Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 19 de 19
Filter
1.
Chinese Journal of Radiological Health ; (6): 197-203, 2022.
Article in Chinese | WPRIM | ID: wpr-973480

ABSTRACT

Objective To study the radioactive concentration of 131I in the air of workplaces where sodium iodide [131I] oral solution was administrated for patients with differentiated thyroid cancer (DTC) in the Department of Nuclear Medicine, and to estimate the internal radiation dose to the staff. Methods Workplaces of radioiodine 131I therapy for DTC patients in the Department of Nuclear Medicine of a hospital were investigated. Air samples in 131I administration areas and treatment wards were collected respectively and were measured by low-background gamma-ray spectrometry to calculate the activity concentration of 131I in the air and to further estimate the internal radiation dose to staffs. Results The activity concentration in the 131I administration area within the first 3 h of administration was 3~187 Bq/m3. During administration and within the first 3 h of administration, the staff exposed in the administration area for 5~30 min received an internal radiation dose of 0.08~0.50 μSv and 0.00~0.04 μSv, respectively. The highest activity concentration of 131I in the air of the ward was measured on the day of administration, reaching 3091 Bq/m3. After patients were discharged, the activity concentration in the ward gradually decreased to 10~242 Bq/m3 within 48 h. Within 48 h after patients were discharged, the staff exposed in the ward for 5~30 min received an internal radiation dose of 0.01~14.11 μSv. Conclusion A high activity concentration of 131I in the air was recorded during administration for DTC patients in radioiodine 131I therapy, and thus we recommend remote instructed administration or administration through a shielded window. We also recommend that non-treatment related personnel except medical staffs should not enter the ward during patients’ hospitalization at which the activity concentration of 131I in the ward was the highest. After patients were discharged, a delayed entry into the ward is recommended to reduce the internal radiation dose.

2.
Chinese Journal of Radiological Medicine and Protection ; (12): 385-390, 2022.
Article in Chinese | WPRIM | ID: wpr-932615

ABSTRACT

Objective:To conduct radiation detection and dose assessment in selective internal radiotherapy with 90Y resin microspheres for the purpose of providing a reference for radiological protection. Methods:The dose rates from radiotherapy with 90Y resin microspheres were detected in the process of each operation at different distances from the body surface of patients the levels of dose to the persons concerned were compared with the relevant national regulations and standards. Results:The estimated dose rates were 1.12-454 μSv/h during 90Y resin microspheres dispensing and 2.06-58.2 μSv/h during surgical procedure. The dose rates at 0.5 h after surgery were 22.7-64.1 μSv/h at 5 cm and 0.82-2.55 μSv/h at 1 m from three patient′s body surface. Assuming treating 200 patients a year, the annual individual effective dose to the radiation workers was 0.12-1.03 mSv/year. The annual individual effective dose to the public, comforters and carers of patients was 0.02-0.24 mSv/year after release of a patient. Conclusions:During the treatment, nursing and release of patients, the radiation doses to workers, carers and the public are lower than the individual dose limit given in the GB18871-2002 basic standards for protection against ionizing radiation and for the safety of radiation sources and the management target value set by of the relevant medical institutions.

3.
China Occupational Medicine ; (6): 454-2022.
Article in Chinese | WPRIM | ID: wpr-965136

ABSTRACT

@#Abstract: Objective ( ) To evaluate the internal exposure levels and risk in nuclear medicine workers NMWs engaged in Methods radionuclide therapy in Guangdong Province. A total of 61 NMWs from eight hospitals in Guangdong Province were selected as the study subjects using the convenient sampling method. The 0.364 MeV full energy peak efficiency was detected in ( ) in vitro , - deltoid muscle of right upper arm as background and thyroid gland by direct measurement method and the iodine 131 (131 ) Results ,131 I activity in thyroid gland was calculated to evaluate the internal irradiation level. Among the 61 NMWs I was , detected in the thyroid gland of four nuclear medical staffs in three hospitals and the detection rate was 6.6%. The median and - [M( P-P )] 131 ( - ) 0 100 percentile 0 100 of thyroid I activity were 42.9 35.1 47.1 Bq. When assuming that the monitoring period was , M( P-P ) ( - ) , 30 days the 0 100 of single committed effective dose in thyroid gland was 0.014 0.011 0.015 mSv and the annual dose ( - ) Conclusion of internal irradiation was 0.162 0.132 0.180 mSv/a. The internal exposure of NMWs in the eight hospitals in ( ) , Guangdong Province meets the annual effective dose limits ≤20.000 mSv/a . However it is necessary to pay attention to the internal radiation protection of NMWs and take reasonable protective measures to reduce the internal exposure risk of NMWs.

4.
Chinese Journal of Hepatology ; (12): 648-658, 2021.
Article in Chinese | WPRIM | ID: wpr-888408

ABSTRACT

Liver malignant tumors are one of the most common causes of cancer-related deaths in China. Selective internal yttrium-90 radioembolization therapy ((90)Y-SIRT) is a kind of promising local minimally invasive method, and its effectiveness and safety has been confirmed in clinical application over the past two decades. Moreover, it has been approved by the U.S. National Comprehensive Cancer Network and other international guidelines for the topical treatment of patients with liver malignancies. Taking into account the complexity of the (90)Y-SIRT and the need for multidisciplinary collaboration to improve the safety and success rate of treatment, the Nuclear Medicine Expert Committee of the Chinese society of Clinical Oncology, along with Beijing Nuclear Medicine Quality Control and Improvement Center invited experts from surgical oncology, interventional medicine, nuclear medicine, and other related fields to discuss and form a consensus on the clinical diagnosis, treatment and management, which mainly included definition, indications and contraindications, treatment procedures, postoperative follow-up, adverse reactions and complications, radiation safety management, etc. Herein, we provide the reference guidance to establish (90)Y-SIRT standardized management and treatment system various units for relevant practitioners.


Subject(s)
Humans , Carcinoma, Hepatocellular/radiotherapy , China , Consensus , Liver Neoplasms/radiotherapy , Microspheres , Yttrium Radioisotopes
5.
Chinese Journal of Radiological Medicine and Protection ; (12): 906-911, 2021.
Article in Chinese | WPRIM | ID: wpr-910415

ABSTRACT

Objective:To understand the activity concentration of 131I aerosol in the air of the iodine treatment workplace and estimate the internal dose of 131I inhaled by medical staff in nuclear medicine. Methods:Using CF-1001BRL portable large capacity air sampler, the 131I aerosol in the iodine treatment workplace of nuclear medicine department of 6 hospitals in Shandong province was collected by iodine box, and the HPGe-γ energy spectrometer was used to measure the samples. The 131I activity concentration in iodine treatment workplace at 6 hospitals was obtained, and the internal dose to medical staff was estimated. Results:The 131I activity concentration in the air in iodine treatment workplaces at 6 hospitals ranged from 3.64 to 2.94×10 3 Bq/m 3. The 131I activity concentration in the controlled area (ward, patient passageway, subpacking room, operation administration room) was significantly higher than that in the supervised area. The highest 131I activity concentration, 2.62×10 2 Bq/m 3, in the supervised area was found in the medical care passageway. The estimated effective dose to nuclear medicine workers was 0.07-5.68 mSv, not exceeding the national limit. Conclusions:The phenomenon of 131I aerosol contamination still exists in the iodine treatment workplaces of nuclear medicine departments in hospitals, so it is necessary to carry out internal radiation monitoring for nuclear medicine departments all around the country, and explore more reasonable protection standards and methods.

6.
Korean Journal of Radiology ; : 209-222, 2018.
Article in English | WPRIM | ID: wpr-714013

ABSTRACT

Radioembolization using beta-emitting yttrium-90 microspheres is being increasingly used for the treatment of primary and metastatic liver cancers. It is a form of intra-arterial brachytherapy which delivers intense radiation to liver tumors with little embolic effect; this mode of action results in unique post-treatment imaging findings. It is important to understand these imaging findings to avoid misinterpretation of tumor response and to determine further management of the disease. Herein, we discuss the current concepts for assessing tumor response, common post-treatment imaging features, and associated complications following radioembolization.


Subject(s)
Brachytherapy , Liver Neoplasms , Liver , Microspheres
7.
Clinical and Molecular Hepatology ; : 265-272, 2017.
Article in English | WPRIM | ID: wpr-216540

ABSTRACT

Management of hepatocellular carcinoma (HCC) can be maximized with the utilization of multiple treatment modalities including transplant, surgical resection and locoregional therapies including ablative therapies and transarterial embolotherapies. Although transplant and surgical resection offer the best clinical outcomes, a limited number of patients are amenable to these surgical treatment options due to the advanced disease at presentation. Transarterial embolotherapies including conventional transarterial chemoembolization (cTACE), bland transarterial embolization (TAE), drug-eluting beads transarterial chemoembolization (DEB-TACE) and selective internal radiation therapy (SIRT) with Yttrium 90 (⁹⁰Y) have played an increasingly important role for these patients with unresectable HCC. With a better understanding of different transarterial embolotherapies, more personalized and precise treatment should be implemented for these patients with unresectable HCC. In this review, the updated evidence on the current role of each embolotherapy in the treatment of HCC is summarized.


Subject(s)
Humans , Carcinoma, Hepatocellular , Embolization, Therapeutic , Yttrium
8.
Mongolian Medical Sciences ; : 20-24, 2016.
Article in English | WPRIM | ID: wpr-631096

ABSTRACT

Background This study is a multi-centre, open-label, randomised controlled trial that will compare the impact of selective internal radiation therapy (SIRT) using SIR-Spheres® yttrium-90 microspheres versus sorafenib on overall survival in patients with locally advanced hepatocellular carcinoma (HCC). A definitive RCT comparing the 2 most promising therapies in locally-advanced HCC will impact on outcomes in a large number of patients and change clinical practice. This will also pave the way for future trials in combined modality therapies in HCC. Methods The study is structured so that patients with locally advanced HCC, who satisfy the study eligibility criteria, will be randomised to receive either: Treatment Arm A: Oral Sorafenib therapy at a dose of 400 mg b.i.d until disease progression, no further response, complete regression or unacceptable toxicity or Treatment Arm B: A single administration of SIR-Spheres into the liver targeted at HCC in the liver by the trans-arterial route. Results Twenty patients treated with 90Y-RE and nineteen patients received Sorafenib at our institution from 14 March 2011, and 30 June 2016 were included. Data from 39 consecutive patients were analyzed. The majority of patients were Child Pugh class B(90%), Barcelona Clinic liver Cancer(BCLC) stage C(58.5%) and Okuda class I (89.5%). Approximately 71% patients diagnosed in IIIa stage and 70% of patients had HBV infection. In the analysis for best response, three of 20 patients in the SIRT group (15%) achieved a partial response 7 of 19 patients (46%) had stable disease, whereas in Sorafenib group, two of 19 patients in the SIRT group (12%) achieved a partial response 9 of 19 patients (39%) had stable disease. Conclusion This study shows the potential efficacy of SIR-Spheres and sorafenib. In summary, selective internal radiation therapy (SIRT) using SIR-Spheres is a promising treatment for well selected patients with unresectable HCC. Sorafenib is effective for the patients with locally advanced HCC without portal vein thrombosis (PVT).

9.
Environmental Health and Toxicology ; : e2016001-2016.
Article in English | WPRIM | ID: wpr-197523

ABSTRACT

OBJECTIVES: To investigate the accuracy and scientific validity of the current very low risk factor for hereditary diseases in humans following exposures to ionizing radiation adopted by the United Nations Scientific Committee on the Effects of Atomic Radiation and the International Commission on Radiological Protection. The value is based on experiments on mice due to reportedly absent effects in the Japanese atomic bomb (Abomb) survivors. METHODS: To review the published evidence for heritable effects after ionising radiation exposures particularly, but not restricted to, populations exposed to contamination from the Chernobyl accident and from atmospheric nuclear test fallout. To make a compilation of findings about early deaths, congenital malformations, Down’s syndrome, cancer and other genetic effects observed in humans after the exposure of the parents. To also examine more closely the evidence from the Japanese A-bomb epidemiology and discuss its scientific validity. RESULTS: Nearly all types of hereditary defects were found at doses as low as one to 10 mSv. We discuss the clash between the current risk model and these observations on the basis of biological mechanism and assumptions about linear relationships between dose and effect in neonatal and foetal epidemiology. The evidence supports a dose response relationship which is non-linear and is either biphasic or supralinear (hogs-back) and largely either saturates or falls above 10 mSv. CONCLUSIONS: We conclude that the current risk model for heritable effects of radiation is unsafe. The dose response relationship is non-linear with the greatest effects at the lowest doses. Using Chernobyl data we derive an excess relative risk for all malformations of 1.0 per 10 mSv cumulative dose. The safety of the Japanese A-bomb epidemiology is argued to be both scientifically and philosophically questionable owing to errors in the choice of control groups, omission of internal exposure effects and assumptions about linear dose response.


Subject(s)
Animals , Humans , Mice , Accidental Falls , Asian People , Down Syndrome , Epidemiology , Genetic Diseases, Inborn , Nuclear Weapons , Parents , Radiation, Ionizing , Risk Factors , Survivors , United Nations
10.
Korean Journal of Radiology ; : 472-488, 2016.
Article in English | WPRIM | ID: wpr-29168

ABSTRACT

Hepatocellular carcinoma is the most common primary liver cancer and it represents the majority of cancer-related deaths in the world. More than 70% of patients present at an advanced stage, beyond potentially curative options. Ytrrium-90 selective internal radiation therapy (Y90-SIRT) with glass microspheres is rapidly gaining acceptance as a potential therapy for intermediate and advanced stage primary hepatocellular carcinoma and liver metastases. The technique involves delivery of Y90 infused glass microspheres via the hepatic arterial blood flow to the appropriate tumor. The liver tumor receives a highly concentrated radiation dose while sparing the healthy liver parenchyma due to its preferential blood supply from portal venous blood. There are two commercially available devices: TheraSphere® and SIR-Spheres®. Although, Y90-SIRT with glass microspheres improves median survival in patients with intermediate and advanced hepatocellular carcinoma and has the potential to downstage hepatocellular carcinoma so that the selected candidates meet the transplantable criteria, it has not gained widespread acceptance due to the lack of large randomized controlled trials. Currently, there are various clinical trials investigating the use of Y90-SIRT with glass microspheres for treatment of hepatocellular carcinoma and the outcomes of these trials may result in the incorporation of Y90-SIRT with glass microspheres into the treatment guidelines as a standard therapy option for patients with intermediate and advanced stage hepatocellular carcinoma.


Subject(s)
Humans , Carcinoma, Hepatocellular , Glass , Liver , Liver Neoplasms , Microspheres , Neoplasm Metastasis
11.
Braz. j. pharm. sci ; 51(2): 339-348, Apr.-June 2015. tab, ilus
Article in English | LILACS | ID: lil-755053

ABSTRACT

Due to interesting therapeutic properties of 177Lu and tumor avidity of tetraphenyl porphyrins (TPPs), 177Lu-tetraphenyl porphyrin was developed as a possible therapeutic compound. 177Lu of 2.6-3 GBq/mg specific activity was obtained by irradiation of natural Lu2O3sample with thermal neutron flux of 4 × 1013 n.cm-2.s-1. Tetraphenyl porphyrin was synthetized and labeled with 177Lu. Radiochemical purity of the complex was studied using Instant thin layer chromatography (ITLC) method. Stability of the complex was checked in final formulation and human serum for 48 h. The biodistribution of the labeled compound in vital organs of wild-type rats was studied up to 7 d. The absorbed dose of each human organ was calculated by medical internal radiation dose (MIRD) method. A detailed comparative pharmacokinetic study was performed for 177Lu cation and [177Lu]-TPP. The complex was prepared with a radiochemical purity: >97±1% and specific activity: 970-1000 MBq/mmol. Biodistribution data and dosimetric results showed that all tissues receive approximately an insignificant absorbed dose due to rapid excretion of the complex through the urinary tract. [177Lu]-TPP can be an interesting tumor targeting agent due to low liver uptake and very low absorbed dose of approximately 0.036 to the total body of human...


Devido às propriedades interessantes do 177Lu e da avidez tumoral das tetrafenil porfirinas (TPP), desenvolveu-se a 177Lu-tetrafenil porfirina como composto terapêutico potencial. 177Lu de atividade específica de 2,6-3 GBq/mg foi obtido por irradiação de amostra de Lu2O3 com fluxo térmico de nêutrons de 4 × 1013 n.cm-2.s-1. Sintetizou-se a tetrafenil porfirina e marcou-se com 177Lu. A pureza radioquímica do complexo foi estudada usando método de Cromatografia Instantânea de Camada Delgada ( ITLC). A estabilidade do complexo foi checada na formulação final e no ser humano por 48 h. A biodistribuição do composto marcado em órgãos vitais de ratos do tipo selvagem foi estudada por mais de 7 dias. A dose absorvida para cada órgão humano foi calculada pelo método da Dose Médica de Radiação Interna (MIRD). Estudo farmacocinético comparativo detalhado foi efetuado para o cátion 177Lu e para o [177Lu]-TPP. O complexo foi preparado com pureza radioquímica >97±1% e atividade específica de 970-1000 MBq/mmol. Os dados de biodistribuição e os resultados dosimétricos mostraram que todos os tecidos receberam uma dose absorvida aproximadamente insignificante devido à rápida excreção do complexo pelo trato urinário. O [177Lu]-TPP pode ser um agente interessante de direcionamento do tumor devido à baixa captação pelo fígado e pela dose bem baixa absorvida, de, aproximadamente, 0,036 do corpo humano total...


Subject(s)
Humans , Lutetium , Lutetium/administration & dosage , Lutetium/therapeutic use , Radioisotopes , Radioisotopes/administration & dosage , Radioisotopes/therapeutic use , Radiopharmaceuticals/administration & dosage , Radiopharmaceuticals/therapeutic use , Porphyrins/administration & dosage , Porphyrins/therapeutic use , Uses of Radiation
12.
The Philippine Journal of Nuclear Medicine ; : 19-23, 2011.
Article in English | WPRIM | ID: wpr-633026

ABSTRACT

Hepatocellular carcinoma and metastatic colorectal carcinoma are amongst the more common causes of cancer-related mortality worldwide. Selective internal radiation therapy (SIRT) with 90y microspheres is usually indicated in patients with nonresectable status and extensive colorectal liver metastases that are refractory to chemotherapy or target therapy. Several examinations, including CT, MRI or PET, serum chemical analyses, hepatic angiography and liver-lung shunting study with Tc-99m MAA, are done to ensure appropriateness and safety of therapy. Herein, three cases (two with hepatocellular carcinoma and one with metastatic colorectal cancer), which qualified for SIRT and underwent SPECT-CT, are presented. All of them underwent the necessary pre-therapy work-ups. The CT and PET-CT scans identified the hepatic lesions. The blood tests showed nearly normal hepatic and renal functions, except for the third case with elevated bilirubin level. The hepatic angiograms revealed no significant gastrointestinal shunting. The liver-lung shunting studies computed 10% hepatopulmonary shunt. Together with the patient with an elevated bilirubin level, they received a reduced dose of 90Y microspheres by 20%. After SIRT, bremsstrahlung planar imaging and SPECT-CT were performed to localize the distribution of the 90y microspheres, the findings of which correlated well with the results of the pre-therapy scans. The use of SPECT-CT is recommended for better anatomic localization and functional correlation.


Subject(s)
Humans , Female , Middle Aged , Carcinoma, Hepatocellular , Neoplasms , Adenocarcinoma , Bilirubin , Hematologic Tests , Liver Neoplasms , Microspheres , Positron Emission Tomography Computed Tomography , Sulfhydryl Compounds , Technetium Tc 99m Aggregated Albumin , Tomography, Emission-Computed, Single-Photon
13.
Chinese Journal of Medical Physics ; (6): 1662-1664,1671, 2010.
Article in Chinese | WPRIM | ID: wpr-605017

ABSTRACT

Objective :To study the two common method of internal irradiation for nanometer-iron nuclide,and how to estimation of the absorbed dose for each of them.Methods:We chose the nanometer-iron nuclide emitting β-ray during the decay period,Respectively,Arterial injected into the liver or percutaneous puncture direct inject into the liver.Results:Through the formula,a few nanometer-iron nuclide can produced greater radiation.Conclusion:The estimation of absorbed dose depends on the therapy method.

14.
Nuclear Medicine and Molecular Imaging ; : 164-171, 2008.
Article in Korean | WPRIM | ID: wpr-75857

ABSTRACT

Medical internal radiation dosimetry (MIRD) is an important part of nuclear medicine research field using therapeutic radioisotope. There have been many researches using MIRD for the development of new therapeutic approaches including radiopharmaceutical, clinical protocol, and imaging techniques. Recently, radionuclide therapy has been re-focused as new solution of intractable diseases, through to the advances of previous achievements. In this article, the basic concepts of radiation and internal radiation dosimetry are summarized to help understanding MIRD and its application to clinical application.


Subject(s)
Achievement , Clinical Protocols , Nuclear Medicine , Radiometry
15.
Nuclear Medicine and Molecular Imaging ; : 265-271, 2007.
Article in English | WPRIM | ID: wpr-139581

ABSTRACT

Radionuclide therapy has been an important field in nuclear medicine. In radionuclide therapy, relevant evaluation of internally absorbed dose is essential for the achievement of efficient and sufficient treatment of incurable disease, and can be accomplish by means of accurate measurement of radioactivity in body and its changes with time. Recently, the advances of nuclear medicine imaging and multi?modality imaging processing techniques can provide chance of more accurate and easier measurement of the measures commented above, in cooperation of conventional imaging?based approaches. In this review, basic concept for internal dosimetry using nuclear medicine imaging is summarized with several check points which should be considered in real practice.


Subject(s)
Nuclear Medicine , Radioactivity , Radiometry
16.
Nuclear Medicine and Molecular Imaging ; : 265-271, 2007.
Article in English | WPRIM | ID: wpr-139580

ABSTRACT

Radionuclide therapy has been an important field in nuclear medicine. In radionuclide therapy, relevant evaluation of internally absorbed dose is essential for the achievement of efficient and sufficient treatment of incurable disease, and can be accomplish by means of accurate measurement of radioactivity in body and its changes with time. Recently, the advances of nuclear medicine imaging and multi?modality imaging processing techniques can provide chance of more accurate and easier measurement of the measures commented above, in cooperation of conventional imaging?based approaches. In this review, basic concept for internal dosimetry using nuclear medicine imaging is summarized with several check points which should be considered in real practice.


Subject(s)
Nuclear Medicine , Radioactivity , Radiometry
17.
Nuclear Medicine and Molecular Imaging ; : 120-126, 2006.
Article in Korean | WPRIM | ID: wpr-82571

ABSTRACT

Radionuclide therapy has been continued for treatment of incurable diseases for past decades. Relevant evaluation of absorbed dose in radionuclide therapy is important to predict treatment output and essential for making treatment planning to prevent unexpected radiation toxicity. Many scientists in the field related with nuclear medicine have made effort to evolve concept and technique for internal radiation dosimetry. In this review, basic concept of internal radiation dosimetry is described and recent progress in method for dosimetry is introduced.


Subject(s)
Nuclear Medicine , Radiometry
18.
Yonsei Medical Journal ; : 799-805, 2005.
Article in English | WPRIM | ID: wpr-80422

ABSTRACT

Percutaneous approaches, such as percutaneous ethanol injection and radiofrequency ablation, have been most widely used for hepatocellular carcinoma patients who were not eligible for surgery. New technologies to improve the efficacy are currently needed. 166Holmium is a neutron activated radionuclide, and has several beneficial radiophysical characteristics for internal radiation therapy. 166Holmium-Chitosan complex, in which chitosan is chelated with 166Holmium, was developed as a radiopharmaceutical for cancer therapy. We have conducted a pilot study to evaluate the clinical efficacy of transarterial administration of 166Holmium-Chitosan complex in patients with a single and small (< 3 cm) hepatocellular carcinoma. 166Holmium-Chitosan complex, at a dose of 20 mCi per cm of tumor mass-diameter, was administered through the artery that directly fed the tumor. Twelve patients were treated with a median follow-up duration of 26 (range: 12-61) months. The tumor diameter ranged between 1.5 and 2.5 cm. Ten patients (83%) had complete response and two (17%) had partial response. The median complete response duration was not reached. The median AFP level declined from 83.8 to 8.3 ng/mL within 2 months after treatment. No grade III/IV toxicity was observed. Grade I and II toxicities were observed in four patients (2 abdominal pain, 1 fever, and 1 AST/ALT elevation). No toxic death occurred. This preliminary study shows a promising and durable complete response rate with an acceptable safety profile. Further studies with greater accrual of patients are warranted.


Subject(s)
Middle Aged , Male , Humans , Female , Aged , Adult , alpha-Fetoproteins/metabolism , Tomography, X-Ray Computed , Radiopharmaceuticals/administration & dosage , Pilot Projects , Liver Neoplasms/pathology , Injections, Intra-Arterial , Chitosan/administration & dosage , Carcinoma, Hepatocellular/pathology
19.
Chinese Journal of Bases and Clinics in General Surgery ; (12)2003.
Article in Chinese | WPRIM | ID: wpr-538490

ABSTRACT

Objective To discuss the clinical val ue of internal radiation therapy with hepatic intra-arterial iodine-131 labele d material for the treatment of hepatocellular carcinoma (HCC). Methods This summarized paper was made on literatu re review. Results Iodine-131-lipiodol and several reported iodine-131-labeled antibodies to HCC associated antigens were concentrated in the foci of HCC with a high tumor-to-normal-tissue absorbed dose ratios. No s evere side effects occurred. It was used in various kinds of HCC patients, and m ostly showed a significant tumor response. Survival rate of HCC patients was rai sed in several clinical trials.Conclusion Internal radiotherapy with hepatic intr a-arterial iodine-131 labeled material may be considered as an effective metho d to treat HCC.

SELECTION OF CITATIONS
SEARCH DETAIL